INTRODUCTION  
This manual is furnished to help you understand your security system and become proficient in its  
operation. All users of your security system should read and follow the instructions in this booklet  
and, if possible, practice on the keypad control while your professional installer is on site. Failure to  
do so could result in the security system not working properly. Please keep this booklet in an  
accessible location for the life of the security system. If you do not understand any part of this manual  
you should notify your installing company.  
The SECURITY CONTROL PANEL can be turned on (ARMED) and off (DISARMED) by entering a 4 or 6 digit  
code into the keypad control, which is similar to a telephone keypad. If your security control panel has been so  
programmed, you may be able to turn on (ARM) your system by simply pressing the [STAY] or [EXIT] key.  
The system must always be disarmed using a 4 or 6 digit code.  
The LED keypad includes up to 35 lights and a built-in electronic sounder. These provide specific information  
relating to the status of the security system which is described in the booklet. Understanding what the lights  
and sounds mean will help you to easily operate your system.  
Keep in mind, the level of security you will obtain with this system relates specifically with two major  
factors:  
1. The quantity, quality and placement of security devices attached to this system.  
2. The knowledge you have of the security system and how that knowledge is utilized in a weekly test of  
the complete system.  
You should be aware of the following facts when preparing a safety/security plan for your  
home/business:  
1. Your security system is an electronic device and is subject to failure or malfunction. Do not rely on it  
as your single source of security.  
2. Your system should be tested weekly.  
3. Your system will not work without power.  
4. Warning devices will need to be loud enough, wired correctly, and properly placed to provide  
notification of an alarm event.  
5. Smoke and heat detectors may not detect heat and smoke in all situations.  
6. Use qualified security professionals to install and maintain your security system.  
7. It may be possible to arm the security system without the backup battery connected. Your periodic  
test should be done with AC Power removed to verify the battery is connected and adequately  
charged.  
8. Care should be taken to plug in and restrain the AC transformer after testing.  
Please read the following information and instructions carefully before operating your security control  
system.  
NX-108/116/124E User manual  
Page 3  
04/10/04  
 
 
GE Security  
g
GLOSSARY OF TERMS  
Abort Delay  
An option that allows a delay in reporting to the central station.  
The level of access an individual has when using an alarm panel.  
The location where alarm data is sent during an alarm report.  
An option that allows the keypad to sound a ding-dong whenever an entry/exit  
door is opened.  
Authority Level  
Central Station  
Chime Feature  
Codes  
Can be either User Codes (relating to a person) or Function Codes (a toggle  
switch to turn specific functions on/off). NOTE: A system may have either four-  
digit codes or six-digit codes, but not a mixture of the two.  
An option that allows a special code to be sent to the central station that  
indicates the alarm system is being operated under duress.  
An option that allows the system to be turned on (ARMED) with one or more  
zones open. A system that is ready to be “force armed” will flash the ready  
icon. (Note: Those zones that are not ready will not create an alarm.)  
A Function Code is either a four (4) or six (6) digit code that has been  
programmed by the installer to operate a device.  
Duress Code  
Forced Arming  
Function Code  
Group Bypass  
Instant/Delay  
An option that allows the user to bypass multiple zones with a single operation.  
An option that allows an instant alarm condition for Entry/Exit doors, or grants a  
delay to allow someone to enter/exit the building without an alarm, or before  
entering a user code to disarm.  
Master Code  
Partitioned System  
A master arm/disarm code that can program other user codes.  
A system divided into multiple areas in which its own user or users control each  
area.  
Perimeter  
Quick Arm  
The outer edge of the protected area.  
An option that allows you to turn on (ARM) the security system by pressing  
either the [STAY] or [EXIT] key on the keypad control (for ARMING only) as  
programmed by the installing company.  
User Code  
A four (4) or six (6) digit entry code used to arm or disarm the system.  
NX-108/116/124E User manual  
Page 4  
04/10/04  
 
 
GE Security  
g
KEYPAD DISPLAY & LED’S  
Understanding the lights  
Ready Light Power Light Service Light  
Armed  
Light  
Instant Light  
Fire Light  
Numeric code  
entry keys  
Pull out zone ID Tab  
Zone Lights  
5 function keys  
3 emergency activation keys  
Armed Light  
The armed light is “on” when the system is armed. The armed light is “off” when it is  
disarmed. The armed light will flash when there has been an alarm during the previous arm  
cycle.  
Bypass Light The bypass light is “on” when any zone in this keypad’s partition is bypassed. If the bypass  
light is “off”, no zones are bypassed.  
Cancel Light  
The cancel light will flash during an abort delay time. Entering a code followed by the  
[CANCEL] key during or after an alarm report to the central station will cause the cancel  
light to come on. It will stay on until the central station has received the cancel report.  
NOTE: The cancel feature must be enabled. (See "Cancel/Abort Feature")  
Chime Light  
Exit Light  
The chime light is “on” when the chime feature is “on”; “off” otherwise.  
The exit light is “on” during the exit delay. Please note that the light will flash during the last  
10 seconds of the exit delay as a warning that the time is running out. (The user may want  
to disarm the system if the exit light is flashing in order to prevent an alarm. The user may  
then re-arm the system and exit before the delay expires.)  
Fire Light  
A steady fire light means a fire zone has been faulted. A rapidly flashing fire light means that  
a fire zone is in a trouble condition.  
NX-108/116/124E User manual  
Page 5  
04/10/04  
 
 
GE Security  
g
Power Light  
Ready Light  
The power light is on if the primary power is on. The power light will flash if the system has a  
low battery condition.  
The ready light is “on” when the system is ready to arm and “flashes” if ready to force arm.  
The ready light is “off” when the system is not ready to arm because of a zone(s) being  
faulted.  
Stay Light  
The stay light is illuminated when all interior zones are bypassed.  
Service Light The service light will be “on” if the security system requires service. If the service light is “on,  
press the [*] key followed by the [2] key to determine the service condition. One or more  
zone lights will illuminate indicating what service(s) is required. Call your service provider  
immediately for these problems. Below is a listing of what each digit means in a service  
condition.  
LIGHT  
1
PROBLEM  
SYSTEM FAULT - Press the [1] key. The zone light(s) that is  
illuminated corresponds to the system fault(s) below:  
1
2
3
4
Over Current Fault  
Siren Trouble  
Box Tamper  
5
6
7
8
Expander Low Battery  
Expander Box Tamper  
Expander Trouble  
Ground Fault  
Expander Power  
Note: Faults 1 & 2 are global in nature and will affect all  
partitions of a multi-partition system. Press the [#] key to  
return to the 1 of 8 service lights.  
2
3
ZONE TAMPER - Press the [2] key and the zone light(s) will  
illuminate showing the zone(s) that are tampered. Press the [#]  
key to return to the 1 of 8 service lights.  
ZONE LOW BATTERY - Press the [3] key. The zone light(s)  
will illuminate showing which zone(s) has a low battery. This  
only applies to wireless zones. Press the [#] key to return to the  
1 of 8 service lights.  
4
5
ZONE LOSS OF SUPERVISION - Press the [4] key and the  
zone light(s) will illuminate showing which zone(s) has loss of  
supervision. This only applies to wireless zones. Press [#] key  
to return to the 1 of 8 service lights.  
ZONE TROUBLE - Press the [5] key and the zone light(s) will  
illuminate showing which zone(s) has a trouble condition.  
Press the [#] key to return to the 1 of 8 service lights.  
6 N TELEPHONE FAULT - Press the [6] key. The zone light(s) that  
is illuminated corresponds to the system fault(s) below:  
6
Line Trouble / Line Cut - This light will illuminate when  
there is telephone line trouble or the telephone line has  
been cut. The service light will remain lit until the  
telephone trouble clears and a user code is entered.  
Auxiliary Comm Device Fail - Radio backup has failed.  
7
7 N FAILURE TO COMMUNICATE - This light will illuminate when  
there is a failure to communicate between your system and the  
central station.  
8 N LOSS OF SYSTEM TIME - This light will illuminate when there  
has been a loss of power and your system clock needs to be  
reset.  
EXIT  
Press the [#] key to exit the Service Light mode.  
N Note: This fault is global in nature and will affect all partitions  
of a multi-partition system.  
NX-108/116/124E User manual  
Page 6  
04/10/04  
 
GE Security  
g
Zone Light  
The zone lights are “off” when everything is normal. A zone light will be “on” if the zone has  
been bypassed. If a zone light is “flashing”, that zone is in alarm or has been faulted. If a zone  
light is “flashing” rapidly, it means that the zone is in a trouble condition. Trouble conditions  
are  
Tamper Hardware Low Battery Loss of supervision  
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid “flashing” light for a  
short period of time, followed by a slow “flashing” light.)  
EMERGENCY ACTIVATION KEYS  
NOTES: You must hold these keys for 2 seconds to activate these functions. Your system may not be  
programmed for these activation keys. You should press these keys only in an emergency situation that  
requires response by emergency personnel. If your system is programmed for these functions, the following  
reports can be sent.  
Fire Key – This key can activate the fire alarm when pressed for two seconds. If your system is connected to  
a monitoring center, an emergency report could be sent to that center.  
Auxiliary Emergency Key – This key can activate the auxiliary alarm when pressed for two seconds. If your  
system is connected to a monitoring center, an emergency report could be sent to that center.  
Police (Panic/Hold-Up) Key - This key can sound a local audible alarm when pressed for two seconds. If  
your system is connected to a monitoring center, an emergency report could be transmitted to that center.  
NOTE: Some Panic/Hold-Up alarms are programmed to be silent at the protected site while reporting an  
alarm to the monitoring center. Check with your installing company to determine how your security system will  
respond to the Panic/Hold-Up activation.  
NX-108/116/124E User manual  
Page 7  
04/10/04  
 
 
GE Security  
g
KEYPAD FUNCTIONS  
Arming your system in the “AWAY” mode  
AWAY is used when the user is away from the premise and wants the interior protected. Listed below are the  
steps to arm in the AWAY Mode:  
Step 1 Close all protected doors and windows.  
Ready light will be on or flashing when all protected zones and sensors are secure.  
NOTE: If any zones are bypassed, a sensor in that zone can be violated without  
affecting the ready light.  
The security system will not arm if the ready light is not on or flashing.  
If the power light is off, you have no AC power. Restore power if possible. If not, contact your  
installing company for service.  
If the power light is flashing, you have a battery failure. Contact your installing company for  
service.  
Step 2 Enter your 4 or 6 digit user code to arm the system.  
The armed and exit lights will illuminate.  
You may now leave the building.  
IMPORTANT!  
The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that  
the exit time is about to expire. The user may wish to disarm and rearm the system if more time is  
needed.  
Making the system ready to arm  
If the ready light is not on or if it is flashing, a zone is not secure. To identify this zone check the zone lights.  
A zone light will be “on” if the zone has been bypassed. If a zone light is “flashing”, that zone is in alarm or has  
been faulted. If a zone light is “flashing” rapidly, it means that the zone is in a trouble condition.  
Arming your system in the “STAY mode”  
STAY is used when the user is inside the premise and wants protection around the perimeter. Listed below  
are the steps to arm in the STAY Mode:  
Step 1 Close all protected doors and windows.  
Ready light must be on or flashing when all protected zones and sensors are secure.  
NOTE: If any zones are bypassed, a sensor in that zone can be violated without  
affecting the ready light.  
The security system will not arm if the ready light is not on or flashing.  
If the power light is off, you have no AC power. Restore power if possible. If not, contact your  
installing company for service.  
If the power light is flashing, you have a battery failure. Contact your installing company for  
service.  
Step 2 Enter your 4 or 6 digit user code. (Optional, if programmed.)  
NX-108/116/124E User manual  
Page 8  
04/10/04  
 
 
GE Security  
g
Step 3  
Press the [STAY] key.  
The bypass light will illuminate indicating that all interior zones are bypassed. (All interior  
devices will bypass automatically, giving the user freedom of movement within the interior  
area.)  
For each interior zone bypassed, the corresponding zone light will also illuminate. If any  
zone(s) have been bypassed previously by the user, the light(s) corresponding to the  
bypassed zone(s) will illuminate, alerting the user that a zone(s) may be unprotected and  
can be faulted without an alarm.  
The stay light will also illuminate. Note: normally, all entry/exit doors will be delayed.  
To change entry/exit to “Instant”, press the [STAY] key again.  
The instant light will illuminate indicating that the entry/exit doors have no delay.  
To change entry/exit to “Delayed”, press the [STAY] key again.  
Step 4  
The instant light extinguish indicating that the entry/exit doors are delayed.  
Using the Quick Arm (optional)  
The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user to arm the security system  
without entering a user code. Quick Arm in the AWAY mode is possbile by pressing the [EXIT] key. The  
system can be quick armed in the STAY mode by pressing the [STAY] key. This feature is used for ARMING  
ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc.  
Changing modes while system armed  
Step 1 Pressing the [STAY] key will turn on/off (toggle) a delay on Entry/Exit doors and turn on/off  
(toggle) the instant light.  
Step 2 Press the [BYPASS] key at this time to turn on/off (toggle) all designated interior zones.  
This is only possible if programmed by your installer (“bypass toggle” option set).  
Step 3 When armed, pressing the [EXIT] key will start the Exit delay, enabling you to leave the building.  
This is only possible if programmed by your installer (“re-exit” option set).  
IMPORTANT!  
The instant light needs to be off at this time if you plan on re-entering the building, otherwise you will create an  
alarm. You may re-initiate an entry/exit delay by pressing the [STAY] key again. The instant light will go out.  
Disarming the system  
When you enter the protected area through one of the designated Entry/Exit doors, the keypad control  
will sound a solid tone for the duration of the entry delay time, or until you enter a valid code. After  
entering a valid code, the red armed light will go off and the tone will stop. The security system is now  
DISARMED. If a valid code is not entered before the end of the entry delay, an alarm will occur.  
(NOTE: If the red armed light is flashing during the entry delay, the alarm system has been  
activated in your absence. Leave the building immediately and call your alarm company and/or  
the police from a safe location.)  
NX-108/116/124E User manual  
Page 9  
04/10/04  
 
 
GE Security  
g
CANCEL / ABORT feature (optional)  
The cancel light will flash during an abort delay time. If a code is entered followed by the [CANCEL] key while  
this light is flashing, all abortable reports will stop the communication process. NOTE: The abort feature  
must be enabled. Entering a code followed by the [CANCEL] key during or after an alarm report to the  
central station will cause the cancel light to come on. It will stay on until the central station has received the  
cancel report. NOTE: The cancel feature must be enabled.  
Bypassing zones  
If you wish to bypass one or more zones, this must be done while the system is in the disarmed state. The  
following steps are used for bypassing zones:  
Step 1 Press the [BYPASS] key.  
Step 2 Enter user code, if required (optional). The bypass light flashes.  
Step 3 Enter 1 or 2 digits indicating the zone you wish to bypass. (Example: Press the [1] key for zone 1,  
press [1] - [2] for zone 12.)  
Step 4 Press the [BYPASS] key again.  
Step 5 The corresponding zone light will illuminate indicating the zone has been bypassed. Repeat steps 3  
and 4 for any other zone(s) that need to be bypassed.  
Step 6 Press the [BYPASS] key again -or- press the [#] key to exit the Bypass Mode. The bypass light will  
stop flashing upon exiting the Bypass Mode.  
Group bypass  
By pressing the [BYPASS] key, followed by the [0] [0] key, then the [BYPASS] key again, all zones that are  
designated as group bypass zones will be bypassed. Press the [BYPASS] key again to exit group bypassing.  
Unbypassing  
To manually unbypass zones, perform the bypassing procedure on a zone that is already bypassed. The  
corresponding light for that zone will go off when unbypassed.  
NOTE: All zones will automatically be unbypassed each time the system is disarmed.  
Turning the door chime ON and OFF  
The door chime feature must be enabled by your installer. The door chime is turned on or off by pressing the  
[CHIME] key. If the chime is on, the chime light will be illuminated. If the chime is off, the chime light will be  
off. Each press of the [CHIME] key will toggle the chime feature on/off and produce a momentary ding-dong  
sound.  
NX-108/116/124E User manual  
Page 10  
04/10/04  
 
 
GE Security  
g
ADDING AND CHANGING USER CODES  
Your system must be Disarmed to add/change user codes.  
Step 1  
Step 2  
Press [r]-[5].  
Enter a “Master Arm/Disarm Code”.  
NOTE: For partitioned systems, someone changing the code of another person must  
have access to all or more partitions than the user being changed.  
Step 3  
Step 4  
The ready light will flash.  
Enter the 2 digit (applies to NX4/6/8) or 3 digit (applies to NX8E) “user number” (always enter  
2 digit such as [0] - [3] for user 3, or [1] - [0] - [0] for user 100).  
Step 5  
Step 6  
Enter the new four (4) or six (6) digit “user code”.  
NOTE: To delete a user code, enter [r]-[r]-[r]-[r] for a 4-digit code, or [r]-[r]-[r]-[r]-[r]-[r]  
for a 6-digit code.  
The ready light will flash indicating you are back at Step 4 above. If the code is rejected, the  
sounder will beep 3 times.  
Step 7  
Step 8  
If another “user code” needs to be programmed, return to Step 5.  
Press the [#] key while the ready light is flashing to exit the User Code Programming Mode.  
NX-108/116/124E User manual  
Page 11  
04/10/04  
 
 
GE Security  
g
ASSIGNING USER CODE AUTHORITY LEVELS  
Assign authority levels to users by following the steps below. Assign user codes before assigning authority  
levels. Your system must be in the disarmed state to change user code authority levels.  
Step 1  
Step 2  
Press [r]-[6].  
Enter a “Master Arm/Disarm Code”.  
NOTE: Someone changing the authority of another person can only add or remove  
partition authorization for partitions to which they have access.  
Step 3  
Step 4  
The ready light will flash.  
Enter the 2-digit (applies to NX4/6/8) or 3-digit (applies to NX8E) user number. Always use  
leading zeros when necessary, i.e. "004" for user number 4.  
Step 5  
Lights illuminated indicate the authority levels assigned to this code. An explanation of the  
lights is listed below. You may toggle (turn on/off) the authority level by pressing the number  
for that authority level.  
LIGHT  
AUTHORITY LEVELS IF LIGHT 8 IS OFF  
Reserved (Note: Do not change if on.)  
Arm Only  
1
2
3
4
5
6
7
8
Arm Only After Close Window  
Master Arm/Disarm (can program other codes)  
Arm/Disarm  
Bypass Zones  
Open / Close Reporting  
If this light is on, this code is programmed as a  
function code. Do not change, Press [#] - [#] to exit.  
Step 6  
Step 7  
Press the [r] key. The ready light will flash. This moves you to the partition enable. (The user  
has access in partitions that are illuminated.)  
The illuminated numbers indicate each partition where the user has access. To change any  
of the partitions where the user has access, press numbers corresponding to areas where  
you want to give the user access or deny access. (Example: If zone light #2 is lit, then the  
user is assigned access to partition #2. By pressing the [2] key, the light will go off, denying  
access to partition #2. Refer to chart shown below.  
LIGHT  
PARTITIONS ASSIGNED  
Partition 1  
1
2
3
4
5
6
7
8
Partition 2  
Partition 3  
Partition 4  
Partition 5  
Partition 6  
Partition 7  
Partition 8  
Step 8  
Step 9  
When the partitions are assigned, press the [r] key. This returns you to Step 3 previously  
mentioned. At this point you may enter another user number to assign authority level.  
Repeat Steps 4 - 8 until you have assigned authority levels to all user numbers.  
Press the [#] key to exit the Assigning Authority Level Program.  
NX-108/116/124E User manual  
Page 12  
04/10/04  
 
 
GE Security  
g
OTHER KEYPAD FUNCTIONS  
Setting the keypad tone  
Step 1  
Step 2  
Step 3  
Press the [r] key.  
Press the [0] key. Keypad is now in the “Adjust Tone” mode.  
Pressing the [1] key will make the keypad sounder go to higher tones, pressing the [2] key will  
make the keypad sounder go to lower tones.  
Step 4  
When the desired tone is reached, press the [#] key to set this tone and exit  
from the “Adjust Tone” mode.  
Change partition (optional)  
Step 1  
Step 2  
Step 3  
Step 4  
Step 5  
Press the [r] key.  
Press the [1] key.  
Press a NUMBER key between 1 and 8 to change partitions momentarily.  
If no other key is pressed, it will go back to its standard partition in ten seconds.  
If another key is pressed, the system will remain in the new partition until no keys have been  
pressed for 60 seconds.  
View alarm memory  
Step 1  
Step 2  
Step 3  
Press the [r] key.  
Press the [3] key to display the zone(s) on the keypad that created the last alarm.  
The ALARM MEMORY feature will flash those zones that created alarms and will light steady  
those zones that were bypassed during the last alarm.  
Test function (optional)  
If programmed, this function will perform a battery test, communicator test, and/or a siren test.  
Step 1  
Step 2  
Press [r] [4] [4]. The test will be performed as programmed.  
If the siren test is performed, enter a user code to silence the siren.  
No alarms will be sent and no reports will be sent unless a communicator test is performed, at which  
time a test signal will be sent.  
NX-108/116/124E User manual  
Page 13  
04/10/04  
 
 
GE Security  
g
Detector reset function  
This function is used to reset Smoke Detectors and Zone Troubles. Your system must be Disarmed to use  
the Reset function.  
Step 1  
Step 2  
Press [r]-[7]. Resets have now been performed. The FIRE light will go off if the smoke  
detectors have been reset.  
If the keypad begins beeping, the reset did not execute properly. Enter your code to silence  
the keypad. Wait a few minutes and repeat step 2 to attempt another reset. If the keypad still  
beeps after repeated attempts, please contact your installer.  
Setting the system clock  
Step 1  
Step 2  
Step 3  
Enter [r][9][7].  
Enter [master code].  
Enter the “hour code” which must be two (2) digits.  
Note: The clock is a 24-hour clock. Refer to the following table.  
Time  
Hour Code  
Time  
Hour Code  
Time  
Hour Code  
12:00 Midnight  
00  
8:00 AM  
08  
4:00 PM  
16  
1:00 AM  
2:00 AM  
3:00 AM  
4:00 AM  
01  
02  
03  
04  
9:00 AM  
10:00 AM  
11:00 AM  
12:00 Noon  
09  
10  
11  
12  
5:00 PM  
6:00 PM  
7:00 PM  
8:00 PM  
17  
18  
19  
20  
5:00 AM  
6:00 AM  
7:00 AM  
05  
06  
07  
1:00 PM  
2:00 PM  
3:00 PM  
13  
14  
15  
9:00 PM  
10:00 PM  
11:00 PM  
21  
22  
23  
Step 4  
Enter the “minutes code” which must be two (2) digits.  
Example: 7 minutes after would be entered [0] – [7].  
NX-108/116/124E User manual  
Page 14  
 
04/10/04  
 
GE Security  
g
Setting the system date  
Step 1  
Enter [r] [9][6].  
Step 2  
Step 3  
Enter [master code].  
Enter the “Day of Week “  
1 = Sunday  
3 = Tuesday  
4 = Wednesday  
5 = Thursday 7 = Saturday  
6 = Friday  
2 = Monday  
Step 4  
Enter the “Month Code”. Must always be two (2) digits.  
01 = January  
05 = May  
09 = September  
10 = October  
02 = February 06 = June  
03 = March  
04 = April  
07 = July  
08 = August  
11 = November  
12 = December  
Step 5  
Step 6  
Enter the “Day Code”. Must always be two (2) digits.  
Example: The 5th would be entered as [0] – [5].  
Enter the last two digits of the “Year Code”.  
Example: For 2003 enter [0] – [3].  
KEYPAD CONTROL TONES (BEEPS)  
A sounder is built into the keypad. If programmed, your system keypad may sound for any of the following  
reasons:  
Beeps for all keypresses.  
Sounds a continuous tone during the Entry delay time.  
Pulses when a day zone is violated while the system is disarmed.  
Pulses when a FIRE zone has a trouble condition.  
Beeps 3 times for trying to arm with the “Ready” light off, if “Force Arming” has not been selected.  
Beeps for 1 second or emits a “ding-dong” sound for the “Chime” feature.  
Beeps during an exit delay; beeps rapidly for the last 10 seconds of an exit delay; and beeps 1  
second at the end of the exit delay.  
Pulses when the armed status changes and the AC power is off.  
Pulses when the armed status changes and any zone(s) are bypassed.  
Pulses when the armed status changes and a low battery is detected.  
Pulses when the armed status changes and a Tamper condition is detected.  
Beeps to indicate Telephone Line Cut, if selected.  
Pulses when one or more of the following conditions are detected: Zone or Box Tamper, Low Battery,  
AC Power Fail, or Expander trouble.  
Beeps 3 times every minute indicating a low battery or missing transmitter is detected (if wireless  
device is in system). Entering code will suppress the sounder for 12 hours.  
Entering a valid code will silence the keypad sounder when it is pulsing. The arm/disarm state of your system  
will not change when entering a code to silence a pulsing keypad sounder. Please contact your installer if a  
trouble condition exists.  
NX-108/116/124E User manual  
Page 15  
04/10/04  
 
 
GE Security  
g
APPENDIX A – REFERENCE TABLES  
IMPORTANT  
These reference tables on the following pages  
need to be completed by your installer.  
Keep these tables in a safe place!  
Installing/Service Company  
Address  
: ______________________________  
: ______________________________  
______________________________  
: ______________________________  
: ______________________________  
: ______________________________  
Telephone number  
Name central station  
Telephone number central station  
Function codes programmed  
Function code Controls function (action)  
Entry/exit delay times in seconds :  
Exit delay time:  
Entry delay time:  
Secondary Exit delay time:  
Secondary Entry delay time:  
This system counts ______ zones  
Programmed functions:  
Abort delay  
Forced arming  
Battery test  
Cancel alarm  
Group bypass  
Quick arm  
Change partitions (LED)  
Chime  
Communicator test  
Manual fire alarm  
Manual medical alarm  
Manual panic alarm  
Re Exit  
Service Light/Message enabled  
Siren test  
NX-108/116/124E User manual  
Page 16  
 
04/10/04  
 
GE Security  
g
Zone descriptions  
Zone 1  
Zone 2  
Zone 3  
Zone 4  
Zone 5  
Zone 6  
Zone 7  
Zone 8  
Zone 9  
Zone 10  
Zone 11  
Zone 12  
Zone 13  
Zone 14  
Zone 15  
Zone 16  
Zone 17  
Zone 18  
Zone 19  
Zone 20  
Zone 21  
Zone 22  
Zone 23  
Zone 24  
NX-108/116/124E User manual  
Page 17  
 
04/10/04  
EMEA Distribution is a division of GE Security EMEA bvba  
COPYRIGHT ©2004  
© GE Security EMEA bvba. All rights reserved. GE Security EMEA bvba grants the right to reprint this  
manual for internal use only. GE Security EMEA bvba reserves the right to change information without  
notice.  
 

Eiki Projector LC SVGA870U User Manual
Electro Voice Portable Speaker DML 1122A Series User Manual
Extron electronic Musical Instrument Amplifier HDMI DA2 User Manual
Extron electronic Switch FOX T USW 103 User Manual
Fellowes Paper Shredder CC4 User Manual
Fostex Speaker G9962ZX User Manual
Fundex Games Board Games Squeezed Out User Manual
GE Caller ID Box 2 9079 User Manual
GE Cell Phone NX 7002 User Manual
Gemini Stereo Amplifier PA 7000 User Manual